Concord 4
Installation Manual
80
Force armed (06104 to 06604)
Default setting is Off.
When this setting is on, the panel reports to the central monitoring station when you “force arm” the system.
Note: Forced arming occurs if you press BYPASS when arming the system with open sensors/zones protesting. Auto-forced
arming occurs when you do not press BYPASS when arming the system with open sensors/zones protesting, then leave
through an entry/exit door and the arming protest period expires. This causes the system to automatically bypass the
open (protesting) sensors. Autoforced arming always reports to the central monitoring station. Autoforced arming has
not been investigated by UL.
To turn the setting off or on, do the following:
1. With the display showing FORCE ARMED OFF/ON (current setting), press 1 (off) or 2 (on).
2. The display flashes the entered setting. Press # and the display shows the new setting.
Latchkey format (06105 to 06605)
Default setting is Off.
This setting determines whether the selected partition is set up for basic (off) or advanced (on) latchkey
opening report operation.
Basic. If the partition is armed by entering 2 (or
3) + CODE, disarming using a designated latchkey user
code or keyfob within an assigned time schedule sends a page.
Arming the partition by entering 2 (or
3) + CODE + 6 (Latchkey) sends a page.
If the partition is armed by entering 2 (or
3) + CODE + 6 (Latchkey), disarming using a designated
latchkey user code or keyfob inside or outside of an assigned time schedule sends a page.
Advanced. Arming the partition by entering 2 (or
3) + CODE + 6 (Latchkey) within an assigned time
schedule sends a page.
Refer to the Concord 4 User Manual for complete latchkey setup and operation.
To turn the setting off or on, do the following:
1. With the desired partition selected, press A or B until the display shows LATCHKEY FORMAT OFF/
ON (current setting). Press 1 (off—basic) or 2 (on—advanced).
2. The display flashes the entered setting. Press # and the display shows the new setting.
Freeze alarm (06106 to 06606)
Default setting is Off.
This setting determines whether the panel reports a freeze alarm to the central station or pager, when the
selected partition’s energy saver module detects a temperature that matches a predetermined setting.
To turn the setting off or on, do the following:
1. With the desired partition selected, press A or B until the display shows FREEZE ALARM OFF/ON
(current setting). Press 1 (off) or 2 (on).
2. The display flashes the entered setting. Press # and the display shows the new setting.