Security applications
2.12 EST3 Installation and Service Manual
ATCK Attack Kit
Power supply
Other factors
Hardware configuration
SDU programming
ACDB/KDC operation
3-SAC
Listed bell
and bell
housing
Tamper loop
Bell circuit
Wires must be in a
metal conduit with no
boxes or other
junctions
Control Panel
3-IDC8/4
3-TAMPRCC Cabinet
Tamp er Sw itch
SAC bus
KPDISP
Figure 2-4: Local certificate
The bell must be positioned where it can be heard from every
arming station in the system. You can use multiple bells if
required.
In mercantile alarm systems that do not provide a remote alarm
transmission connection, you must mount the alarm housing on
the outside of the building in a location that is accessible, is not
more than four stories above street level, and is visible from the
public street or highway.
You may locate the alarm housing as high as the seventh floor,
provided you do one of the following:
Mount a second alarm sounding device and housing intended
for outside service adjacent to the premises or area of the
building in which the alarm system is installed
Mount a second alarm sounding device and housing intended
for inside service within the premises