Appendix E: Device types to personality codes correlation
260 Vigilant VS1 and VS2 Technical Reference Manual
Model Device type Personality code
MAB Alarm (1) Alarm - NO latching (Class B)
MAB Alarm Class A (9) Alarm - NO latching (Class A)
MAB Continuous Non-Silenceable (16) Signal - supervised output (Class B)
MAB Continuous Non-Silenceable
(Latched)
(16) Signal - supervised output (Class B)
MAB Continuous Non-Silenceable
Class A
(15) Signal - supervised output (Class A)
MAB Continuous Non-Silenceable
Class A (Latched)
(15) Signal - supervised output (Class A)
MAB Continuous Silenceable (16) Signal - supervised output (Class B)
MAB Continuous Silenceable Class A (15) Signal - supervised output (Class A)
MAB Heat (1) Alarm - NO latching (Class B)
MAB Heat Class A (9) Alarm - NO latching (Class A)
MAB Monitor (3) Active - NO nonlatching (Class B)
MAB Monitor Class A (11) Active - NO nonlatching (Class A)
MAB None (0) No Personality
MAB Pull Station (1) Alarm - NO latching (Class B)
MAB Pull Station Class A (9) Alarm - NO latching (Class A)
MAB Remote AC Fail (3) Active - NO nonlatching (Class B)
MAB Remote AC Fail Class A (11) Active - NO nonlatching (Class A)
MAB Remote Drill (3) Active - NO nonlatching (Class B)
MAB Remote Reset (3) Active - NO nonlatching (Class B)
MAB Remote Signal Silence (3) Active - NO nonlatching (Class B)
MAB Smoke (1) Alarm - NO latching (Class B)
MAB Smoke Class A (9) Alarm - NO latching (Class A)
MAB Supervised Output (16) Signal - supervised output (Class B)
MAB Supervised Output (Latched) (16) Signal - supervised output (Class B)
MAB Supervised Output Class A (15) Signal - supervised output (Class A)
MAB Supervised Output Class A
(Latched)
(15) Signal - supervised output (Class A)
MAB Supervisory Latching (4) Active - NO latching (Class B)
MAB Supervisory Latching Class A (12) Active - NO latching (Class A)
MAB Supervisory Nonlatching (3) Active - NO nonlatching (Class B)
MAB Supervisory Nonlatching Class A (11) Active - NO nonlatching (Class A)
MAB Water Flow (2) Alarm - NO delayed latching (Class B)

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the GE Security Vigilant VS2 and is the answer not in the manual?

GE Security Vigilant VS2 Specifications

General IconGeneral
BrandGE Security
ModelVigilant VS2
CategoryControl Panel
LanguageEnglish

Related product manuals