Appendix E: Device types to personality codes correlation
Vigilant VS1 and VS2 Technical Reference Manual 263
Model Device type Personality code
UM Continuous Non-Silenceable
(Latched)
(16) Signal - supervised output (Class B)
UM Continuous Non-Silenceable
Class A
(15) Signal - supervised output (Class A)
UM Continuous Non-Silenceable
Class A (Latched)
(15) Signal - supervised output (Class A)
UM Continuous Silenceable (16) Signal - supervised output (Class B)
UM Continuous Silenceable Class A (15) Signal - supervised output (Class A)
UM Heat (1) Alarm - NO latching (Class B)
UM Heat Class A (9) Alarm - NO latching (Class A)
UM Monitor (3) Active - NO nonlatching (Class B)
UM Monitor Class A (11) Active - NO nonlatching (Class A)
UM None (0) No Personality
UM Pull Station (1) Alarm - NO latching (Class B)
UM Pull Station Class A (9) Alarm - NO latching (Class A)
UM Relay Non-Silenceable (8) Signal - dry contact output
UM Relay Non-Silenceable (Latched) (8) Signal - dry contact output
UM Relay Silence (8) Signal - dry contact output
UM Remote AC Fail (3) Active - NO nonlatching (Class B)
UM Remote AC Fail Class A (11) Active - NO nonlatching (Class A)
UM Remote Drill (3) Active - NO nonlatching (Class B)
UM Remote Reset (3) Active - NO nonlatching (Class B)
UM Remote Signal Silence (3) Active - NO nonlatching (Class B)
UM Smoke (1) Alarm - NO latching (Class B)
UM Smoke Class A (9) Alarm - NO latching (Class A)
UM Supervised Output (16) Signal - supervised output (Class B)
UM Supervised Output (Latched) (16) Signal - supervised output (Class B)
UM Supervised Output Class A (15) Signal - supervised output (Class A)
UM Supervised Output Class A
(Latched)
(15) Signal - supervised output (Class A)
UM Supervisory Latching (4) Active - NO latching (Class B)
UM Supervisory Latching Class A (12) Active - NO latching (Class A)
UM Supervisory Nonlatching (3) Active - NO nonlatching (Class B)
UM Supervisory Nonlatching Class A (11) Active - NO nonlatching (Class A)
UM Unlatch Outputs (3) Active - NO nonlatching (Class B)

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the GE Security Vigilant VS2 and is the answer not in the manual?

GE Security Vigilant VS2 Specifications

General IconGeneral
BrandGE Security
ModelVigilant VS2
CategoryControl Panel
LanguageEnglish

Related product manuals