CE LITE-UM-251-9370
6 DISASSEMBLY AND REASSEMBLY
6-15
(5) Move the carriage to the left end.
Fix the Y-exible cable with double-sided tapes at a position where the left edge of the Y-exible
cable is within the range as shown in the picture below.
Conrm that the left edge of
the cable is within this range.
300 mm from the right edge
Fix the Y-exible cable at the two
positions as shown below.
(6) Reattach the other parts in the reverse order in which they were detached.