EasyManua.ls Logo

GW Instek APS-7000 Series - [:Source]:Current:limit:rms:mode; [:Source]:Current:limit:rms:time

GW Instek APS-7000 Series
152 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
APS-7000 Programming Manual
100
Query Syntax
[:SOURce]:CURRent:LIMit:RMS[:AMPLitude]?
[MINimum|MAXimum]
Parameter
<NR2>
Irms in A.
MINimum
Minimum settable current
MAXimum
Maximum settable current
Return parameter
<NR2>
Returns the Irms.
Example
CURR:LIM:RMS?
4.20
Returns the Irms setting.
[:SOURce]:CURRent:LIMit:RMS:MODE
Set
Query
Description
Sets or queries IRMS OC-Fold enable.
Syntax
[:SOURce]:CURRent:LIMit:RMS:MODE
{<bool>|OFF|CONTinuous}
Query Syntax
[:SOURce]:CURRent:LIMit:RMS:MODE?
Parameter/
Return parameter
<bool>
|OFF|ON OC-Fold on(1)/off(0)
OFF
OC-Fold off
CONTinuous
OC-Fold enable
Example
:CURR:LIM:RMS:MODE CONT
Sets OC-Fold enable.
[:SOURce]:CURRent:LIMit:RMS:TIME
Set
Query
Description
Sets or queries IRMS delay time by turn off.
Syntax
[:SOURce]:CURRent:LIMit:RMS:TIME
{<NR2>|MINimum|MAXimum}
Query Syntax
[:SOURce]:CURRent:LIMit:RMS:TIME?
{MINimum|MAXimum}
Parameter
<NR2>
0~10 IRMS delay time in Second
MINimum
Minimum IRMS delay time
MAXimum
Maximum IRMS delay time
Return parameter
<NR2>
Return the IRMS delay time value