REMOTE CONTROL
109
[:SOURce]:SEQuence:CSTep?
[:SOURce]:SEQuence:SPARameter
Sets or queries the parameters for a specified step.
[:SOURce]:SEQuence:SPARameter
{<NR2>,<NR1>|CONSt|KEEP|SWEep,<NR2>,<NR1>|C
ONSt|KEEP|SWEep,<NR2>,<NR1>|CONSt|KEEP|SWE
ep,SIN,<NR1>}
[:SOURce]:SEQuence:SPARameter?
ACV mode: Constant(1) | Keep(2) |
Sweep(3)
DCV. Not applicable. This parameter
will be ignored.
DCV mode: Constant(1) | Keep(2) |
Sweep(3)
Frequency mode: Constant(1) |
Keep(2) | Sweep(3)
<NR2>,<NR1>|CONSt|KEEP|SWEep,<NR2>,<NR1>|
CONSt|KEEP|SWEep,<NR2>,<NR1>|CONSt|KEEP|S
WEep,SIN,<NR1>
Returns the step parameters in the following order:
ACV, ACV mode, DCV, DCV mode, frequency,
frequency mode, SIN, phase.
:SEQ:SPAR?
>+101.0000,KEEP,+0.0000,CONST,+50.0000,CONST,S
IN,0