EasyManuals Logo

GW Instek APS-7000 Series Programming Manual

GW Instek APS-7000 Series
152 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #82 background imageLoading...
Page #82 background image
APS-7000 Programming Manual
82
Return parameter
<NR1>
+0
Ramp mode is disabled.
+1
Time mode
+2
Voltage mode
:SYSTem:CONFigure:RAMP:VOLTage
Set
Query
Description
Sets or queries the ramp Vup and Vdn parameters.
Syntax
:SYSTem:CONFigure:RAMP:VOLTage[:LEVel][:AMPLitu
de] {<NR2>|MINimum|MAXimum,<NR2>|MINimum
|MAXimum}
Query Syntax
:SYSTem:CONFigure:RAMP:VOLTage[:LEVel][:AMPLitu
de]? [MINimum|MAXimum]
Parameter
<NR2>
Vup (Vrms).
MINimum
Minimum Vup.
MAXimum
Maximum Vdn.
<NR2>
Vdn (Vrms).
MINimum
Minimum Vup.
MAXimum
Maximum Vdn.
Return parameter
<NR2>,<NR2>
Returns the Vup,Vdn voltage levels.
Example
:SYST:CONF:RAMP:VOLT?
>+0.2000,+0.3000
Returns the Vup,Vdn values.
:SYSTem:CONFigure:RAMP:TIME
Set
Query
Description
Sets or queries the ramp Tup and Tdn parameters.
Syntax
:SYSTem:CONFigure:RAMP:TIME {<NR2>|
MINimum|MAXimum,<NR2>|MINimum|MAXimum}
Query Syntax
:SYSTem:CONFigure:RAMP:TIME?
[MINimum|MAXimum]
Parameter
<NR2>
Tup in milliseconds
MINimum
Minimum Tup
MAXimum
Maximum Tup
<NR2>
Tdn in milliseconds
MINimum
Minimum Tdn
MAXimum
Maximum Tdn

Table of Contents

Other manuals for GW Instek APS-7000 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the GW Instek APS-7000 Series and is the answer not in the manual?

GW Instek APS-7000 Series Specifications

General IconGeneral
BrandGW Instek
ModelAPS-7000 Series
CategoryAC Power Distribution
LanguageEnglish

Related product manuals