EasyManuals Logo

GW Instek APS-7000 Series Programming Manual

GW Instek APS-7000 Series
152 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #121 background imageLoading...
Page #121 background image
REMOTE CONTROL
121
[:SOURce]:SIMulation:REPeat:COUNt
Set
Query
Description
Sets or queries the repeat count for the Simulation
mode.
Syntax
[:SOURce]:SIMulation:REPeat:COUNt
{<NR1>|MINimum|MAXimum}
Query Syntax
[:SOURce]:SIMulation:REPeat:COUNt?
Parameter/Return
parameter
<NR1>
0 ~ 255 (0 = infinite loop)
MINimum
MAXimum
Example
:SIM:REP:COUN 1
Sets the repeat count to 1.
[:SOURce]:SIMulation:REPeat:ENABle
Set
Query
Description
Turns the repeat function on or off for the
Simulation mode.
Syntax
[:SOURce]:SIMulation:REPeat:ENABle
{<bool>|OFF|ON}
Query Syntax
[:SOURce]:SIMulation:REPeat:ENABle?
Parameter/Return
parameter
OFF | 0
Disabled
ON | 1
Enabled
Example
:SIM:REP:ENAB 1
Enables the repeat function.
[:SOURce]:SIMulation:TRANsition<1|2>
:TIME
Set
Query
Description
Sets or queries the Time parameter of the transition
step for the Simulation mode.
Syntax
[:SOURce]:SIMulation:TRANsition<1|2>:TIME
{<NR2>|MINimum|MAXimum}

Table of Contents

Other manuals for GW Instek APS-7000 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the GW Instek APS-7000 Series and is the answer not in the manual?

GW Instek APS-7000 Series Specifications

General IconGeneral
BrandGW Instek
ModelAPS-7000 Series
CategoryAC Power Distribution
LanguageEnglish

Related product manuals