REMOTE CONTROL
125
Remote Sense Command (APS-7200, 7300 only)
:RSENse:[STATe] ..................................................... 125
:RSENse:[STATe]
Set
Query
Description
Sets or queries the state of remote sense.
Syntax
:RSENse[:STATE]{<bool>|OFF|ON}
Query Syntax
:RSENse[:STATE]?
Parameter
OFF|0
Turns the output off.
ON|1
Turns the output on.
Return parameter
<bool>
Returns status of the instrument.