APS-7000 Programming Manual
84
Parameter
0 | DISable
Disables surge/dip mode.
1 | MANual
Sets the surge/dip mode to manual.
2 | AUTO
Sets the surge/dip mode to auto.
Return parameter
<NR1>
+0
Surge/dip mode off.
+1
Manual mode.
+2
Auto mode.
:SYSTem:CONFigure:SDIP:SITE
Set
Query
Description
Sets or queries the surge/dip site (equivalent to the
T1 time setting using the panel controls).
Syntax
:SYSTem:CONFigure:SDIP:SITE
{<NR2>|MINimum|MAXimum}
Query Syntax
:SYSTem:CONFigure:SDIP:SITE?
[MINimum|MAXimum]
Parameter
<NR2>
Site number:
0 ~99ms(manual SDIP mode)
0 ~22ms(auto SDIP mode)
MINimum
Minimum site 0
MAXimum
Maximum site 99(manual)/22(auto)
Return parameter
<NR1>
Returns the site in msecs (+NR1).
:SYSTem:CONFigure:SDIP:VOLTage
Set
Query
Description
Sets or queries the surge/dip voltage level.
Syntax
:SYSTem:CONFigure:SDIP:VOLTage[:LEVel][:AMPLitud
e] {<NR2>|MINimum|MAXimum}
Query Syntax
:SYSTem:CONFigure:SDIP:VOLTage[:LEVel][:AMPLitud
e]? [MINimum|MAXimum]
Parameter
<NR2>
ACV level from 0V.
MINimum
Minimum voltage (0V)
MAXimum
Maximum voltage (set voltage range)
Return parameter
<NR1>
Returns the surge/dip voltage (+NR1).

Table of Contents

Other manuals for GW Instek APS-7000 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the GW Instek APS-7000 Series and is the answer not in the manual?

GW Instek APS-7000 Series Specifications

General IconGeneral
BrandGW Instek
ModelAPS-7000 Series
CategoryAC Power Distribution
LanguageEnglish

Related product manuals