122
Query Syntax
[:SOURce]:SIMulation:TRANsition<1|2>:TIME?
[MINimum|MAXimum]
Parameter/Return
parameter
<NR2>
Time of the step in seconds
MINimum
0
MAXimum
99.99s
Example
:SIM:TRAN1:TIME 1
Sets the step time to 1 second.
[:SOURce]:VOLTage:LIMit:RMS
Set
Query
Description
Sets or queries the voltage limit for the continuous
operation mode.
Syntax
[:SOURce]:VOLTage:LIMit:RMS
{<NR2>|MINimum|MAXimum}
Query Syntax
[:SOURce]:VOLTage:LIMit:RMS?
[MINimum|MAXimum]
Parameter
<NR2>
Vrms.
MINimum
Minimum voltage limit
MAXimum
Maximum voltage limit
Return parameter
<NR2>
Returns the voltage limit.
Example
VOLT:LIM:RMS?
600.00
Returns the Vrms limit.
[:SOURce]:VOLTage:RANGe
Set
Query
Description
Sets or queries the voltage range for the
continuous operation mode.
Syntax
[:SOURce]:VOLTage:RANGe
{<NR1>|R155|R310|R600|AUTO}
Query Syntax
[:SOURce]:VOLTage:RANGe? [MINimum|MAXimum]
Parameter
<NR1>
Voltage range (155, 310, 600).
R155
155 V range
R310
310 V range
R600
600V range

Table of Contents

Other manuals for GW Instek APS-7000 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the GW Instek APS-7000 Series and is the answer not in the manual?

GW Instek APS-7000 Series Specifications

General IconGeneral
BrandGW Instek
ModelAPS-7000 Series
CategoryAC Power Distribution
LanguageEnglish

Related product manuals