APS-7000 Programming Manual
110
[:SOURce]:SEQuence:STEP
Set
Query
Description
Sets or queries the current step number.
Syntax
[:SOURce]:SEQuence:STEP
{<NR1>|MINimum|MAXimum}
Query Syntax
[:SOURce]:SEQuence:STEP? [MINimum|MAXimum]
Parameter/Return
parameter
<NR1>
Step number
MINimum
Minimum step number
MAXimum
Maximum step number
Example
:SEQ:STEP 1
Sets the step number to 1.
[:SOURce]:SIMulation:ABNormal:CODE
Set
Query
Description
Sets the external trigger output for the abnormal
step parameter. This option is only applicable
when in the Simulation mode.
Syntax
[:SOURce]:SIMulation:ABNormal:CODE
{<NR1>|MINimum|MAXimum}
Query Syntax
[:SOURce]:SIMulation:ABNormal:CODE?
[MINimum|MAXimum]
Parameter
<NR1>
External trigger output, HI=1, LO=0.
MINimum
LO, 0
MAXimum
HI, 1
Return parameter
+0
LO
+1
HI
Example
SIM:ABN:CODE 1
[:SOURce]:SIMulation:ABNormal
:FREQuency
Set
Query
Description
Sets or queries the frequency of the abnormal step
of the simulation mode.

Table of Contents

Other manuals for GW Instek APS-7000 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the GW Instek APS-7000 Series and is the answer not in the manual?

GW Instek APS-7000 Series Specifications

General IconGeneral
BrandGW Instek
ModelAPS-7000 Series
CategoryAC Power Distribution
LanguageEnglish

Related product manuals