REMOTE CONTROL
129
The diagram below shows the structure of the
Status registers.
The Status Registers
Questionable Status Register
Condition PTR/NTR Event Enable
0
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
0
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
0
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
0
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
Operation Status Register
Condition PTR/NTR Event Enable
0
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
0
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
0
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
0
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
Warning Status Register
Condition PTR/NTR Event Enable
0
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
0
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
0
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
0
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
Standard Event Status Register
Event Enable
0
1
2
3
4
5
6
7
0
1
2
3
4
5
6
7
Status
Byte
Register
0
1
2
3
4
5
6
7
6
Error
Queue
:
:
:
Output
Buffer
:
:
:
WAR
ERR
QUES
MAV
ESB
OPER
RQS MSS
Service
Request
Enable
Register
0
1
2
3
4
5
6
7
Service
Request
Generation
OC (Over Current)
OT (Over Temperature)
CAL(Calibration data is invalid)
OP (Over Power)
OPC (Operation Complete)
RQC (Request Control)
QUE (Query Error)
DDE (Device Dependent Error)
EXE (Execution Error)
CME (Command Error)
URQ (User Request)
PON (Power ON)
Output overcurrent (RMS)
OT (Over Temperature)
Output OFF after RMS current limiter is activated
Output OFF after peak current limiter is activated
RMS current limiter is operating
Busy status
LOCK status (SYNC status)
Sequence is in the Hold status
Sequence or Simulation is in the Run status
Always 0
Output overcurrent (Peak)
Always 0
Always 0
PU (Device error has occurred)
OPK (Over Peak)
OCP
Output Short
System Wait