REMOTE CONTROL
99
Syntax
[:SOURce]:CURRent:LIMit:PEAK:HIGH
{<NR2>|MINimum|MAXimum}
Query Syntax
[:SOURce]:CURRent:LIMit:PEAK:HIGH?
[MINimum|MAXimum]
Parameter
<NR2>
Ipk-Limit in Arms.
MINimum
Minimum settable peak current limit
MAXimum
Maximum settable peak current limit
Return parameter
<NR2>
Returns the Ipk-Limit value
Example
CURR:LIM:PEAK:HIGH?
16.80
Returns the peak current limit as 16.8Arms.
[:SOURce]:CURRent:LIMit:PEAK:TIME
Set
Query
Description
Sets or queries Ipk-Limit delay time by turn off.
Syntax
[:SOURce]:CURRent:LIMit:PEAK:TIME
{<NR2>|MINimum|MAXimum}
Query Syntax
[:SOURce]:CURRent:LIMit:PEAK:TIME?
{MINimum|MAXimum}
Parameter
<NR2>
0~10 Ipk-Limint delay time in Second
MINimum
Minimum Ipk-Limint delay time
MAXimum
Maximum Ipk-Limint delay time
Return parameter
<NR2>
Return the Ipk-Limint delay time value
Example
:CURR:LIM:PEAK:TIME?
0
Returns Ipk-Limint delay off time as 0Sec.
[:SOURce]:CURRent:LIMit:RMS
[:AMPLitude]
Set
Query
Description
Sets or queries the Irms parameter for the
continuous operation mode.
Syntax
[:SOURce]:CURRent:LIMit:RMS[:AMPLitude]
{<NR2>|MINimum|MAXimum}