APS-7000 Programming Manual
114
Return parameter
<NR1>
Current step
+0 = Initial step
+1 = Normal1 step
+2 = Transition1 step
+3 = Abnormal step
+4 = Transition2 step
+5 = Normal2 step
Example
:SIM:CSTep?
>+1
[:SOURce]:SIMulation:INITial:CODE
Set
Query
Description
Sets the external trigger output for the initial step
parameter. This option is only applicable when in
the Simulation mode.
Syntax
[:SOURce]:SIMulation:INITial:CODE
{<NR1>|MINimum|MAXimum}
Query Syntax
[:SOURce]:SIMulation:INITial:CODE?
[MINimum|MAXimum]
Parameter/Return
parameter
<NR1>
HI=1, LO=0.
MINimum
LO, 0
MAXimum
HI, 1
Example
SIM:INIT:CODE 1
[:SOURce]:SIMulation:INITial:FREQuency
Set
Query
Description
Sets or queries the frequency of the initial step of
the simulation mode.
Syntax
[:SOURce]:SIMulation:INITial:FREQuency
{<NR2>|MINimum|MAXimum}
Query Syntax
[:SOURce]:SIMulation:INITial:FREQuency?
[MINimum|MAXimum]
Parameter/Return
parameter
<NR2>
Frequency of initial step
MINimum
Minimum frequency
MAXimum
Maximum frequency

Table of Contents

Other manuals for GW Instek APS-7000 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the GW Instek APS-7000 Series and is the answer not in the manual?

GW Instek APS-7000 Series Specifications

General IconGeneral
BrandGW Instek
ModelAPS-7000 Series
CategoryAC Power Distribution
LanguageEnglish

Related product manuals