EasyManua.ls Logo

GW Instek APS-7000 Series - [:Source]:Frequency:limit:high; [:Source]:Frequency:triggered

GW Instek APS-7000 Series
152 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
REMOTE CONTROL
101
Example
:CURR:LIM:RMS:TIME?
0
Returns IRMS delay off time as 0Sec.
[:SOURce]:FREQuency:LIMit:HIGH
Set
Query
Description
Sets or queries the frequency upper limit range.
Syntax
[:SOURce]:FREQuency:LIMit:HIGH
{<NR2>|MINimum|MAXimum}
Query Syntax
[:SOURce]:FREQuency:LIMit:HIGH?
[INimum|MAXimum]
Parameter
<NR2>
Frequency in Hz.
MINimum
Minimum settable frequency
MAXimum
Maximum settable frequency
Return parameter
<NR2>
Returns the frequency limit
Example
FREQ:LIM:HIGH?
>60.50
Returns the frequency limit.
[:SOURce]:FREQuency:TRIGgered
Set
Query
Description
Sets or queries the frequency when triggered.
Syntax
[:SOURce]:FREQuency:TRIGgered
{<NR2>(HZ)|MINimum|MAXimum}
Query Syntax
[:SOURce]:FREQuency:TRIGgered?
[MINimum|MAXimum]
Parameter
<NR2>
Frequency in Hz.
MINimum
Minimum settable frequency
MAXimum
Maximum settable frequency
Return parameter
<NR2>
Returns the frequency
Example
:FREQ:TRIG?
>60.50
Returns the frequency setting.

Table of Contents

Other manuals for GW Instek APS-7000 Series

Related product manuals