EasyManua.ls Logo

GW Instek APS-7000 Series - Data|Trace:simulation:store

GW Instek APS-7000 Series
152 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
REMOTE CONTROL
59
Parameter
<NR1>
0~9 (SIM0 ~ SIM9).
MIN
0
MAX
9
Example
:DATA:SIM:REC 1
Loads the data from SIM1.
:DATA|TRACe:SIMulation:STORe
Set
Description
Saves the simulation data. This command is the
equivalent saving a simulation memory in
Simulation mode (SIM0 ~ SIM9).
Syntax
:DATA|TRACe:SIMulation:STORe
{<NR1>|MINimum|MAXimum}
Parameter
<NR1>
0~9 (SIM0 ~ SIM9).
MIN
0
MAX
9
Example
:DATA:SIM:STOR 1
Saves the data from SIM1.

Table of Contents

Other manuals for GW Instek APS-7000 Series

Related product manuals