[:SOURce]:FREQuency[:IMMediate]
Set
Query
Description
Sets or queries the frequency for the immediate
trigger.
Syntax
[:SOURce]:FREQuency[:IMMediate]
{<NR2>(HZ)|MINimum|MAXimum}
Query Syntax
[:SOURce]:FREQuency[:IMMediate]?
[MINimum|MAXimum]
Parameter/Return
parameter
<NR2>
Frequency setting in Hz.
MINimum
Minimum frequency
MAXimum
Maximum frequency
Example
:FREQ
60.00
Sets the frequency of 60Hz.
[:SOURce]:FUNCtion:CSINe:CFACtor
Set
Query
Description
Sets or queries the crest factor setting for the
waveform.
Note:
The :SOURce:FUNCtion:CSINe:TYPE command
must first be used to set the save slot number
(CLP1|2|3) and CFACtor as the waveform type
before this command is executed.
Syntax
[:SOURce]:FUNCtion:CSINe:CFACtor
{CLP1|CLP2|CLP3,<NR2>|MINimum|MAXimum}
Query Syntax
[:SOURce]:FUNCtion:CSINe:CFACtor?
{CLP1|CLP2|CLP3[,MINimum|MAXimum]}
Parameter/Return
parameter
<NR2>
Crest factor
CLP1
Save slot 1
CLP2
Save slot 2
CLP3
Save slot 3
MIN
1.4
MAX
10.0

Table of Contents

Other manuals for GW Instek APS-7000 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the GW Instek APS-7000 Series and is the answer not in the manual?

GW Instek APS-7000 Series Specifications

General IconGeneral
BrandGW Instek
ModelAPS-7000 Series
CategoryAC Power Distribution
LanguageEnglish

Related product manuals