EasyManua.ls Logo

HEIDENHAIN ITNC 530 - CONVERSATIONAL PROGRAMMING - Page 611

HEIDENHAIN ITNC 530 - CONVERSATIONAL PROGRAMMING
713 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
HEIDENHAIN iTNC 530 611
16.4 Program Run
U To go to the first block of the current program to start a block scan,
enter GOTO “0”.
U To select block scan, press the BLOCK SCAN soft key,
or
U Start-up at N: Enter the block number N at which the
block scan should end
U Program: Enter the name of the program containing
block N
U Start-up at: P: Enter the number P at which the
block scan should end if you want to start in a point
table or at a PATTERN DEF block
U Table (PNT): Enter the name of the point table in
which the block scan should end
U Repetitions: If block N is located in a program section
repeat or in a subprogram that is to be run repeatedly,
enter the number of repetitions to be calculated in the
block scan
U To start the block scan, press the machine START
button
U Contour approach (see following section)
Entering a program with the GOTO key
Danger of collision!
If you use the GOTO block number key for going into a
program, neither the TNC nor the PLC will execute any
functions that ensure a safe start.
If you use the GOTO block number key for going into a
subprogram, the TNC will skip the end of the subprogram
(LBL 0)! In such cases you must always use the
mid-program startup function.