All rights reserved HID Global Corporation
HDP5000 High Definition Card Printer/Encoder User Guide L000950 Rev 1.8
201
Reviewing the Telnet Command Table
Telnet Command Command Purpose Command Format
contact Set the contact string. set sysinfo label [<STRING>]
location Set the location string. set sysinfo location [<STRING>]
label Set the label string. set sysinfo label [<STRING>]
sysinfo
from Set all strings from
default or current
settings.
set sysinfo from default|current
name Change the name of a
system log path
set syslog <LOG_NAME> name
<NEW_NAME>
type Change the type of a
system log path. This
starts or stops logging
on start of jobs or on
faults.
set syslog <LOG_NAME> type
[[-]job] [[-]pfault]
dest Change the destination
of a system log path.
This may be set to
none, e-mail, udp or
tcp.
set syslog <LOG_NAME> dest
none|email|udp|tcp
email Change the e-mail
address for e-mail
notification for a
system log path. It
must specify a valid e-
mail address.
set syslog <LOG_NAME> email
<EMAIL>
udp Specify the IP address
of the UPD system
logging program.
set syslog <LOG_NAME> udp
<IPADDRESS>
set
syslog
from Restore system log
path settings from the
default or current
settings.
set syslog from default|current

Table of Contents