Table 9-16 UDP Communication Protocol
Parameter
Description
UDP Protocol Enable
If enabled, the code reader will output data via User Datagram
Protocol (UDP).
UDP Dst IP
The IP address of the PC receiving the output data.
UDP Dst Port
The port of the PC receiving the output data.
9.8.11 Fins
If you select Fins as the communication protocol, you can configure the following
parameters:
Table 9-17 Fins Communication Protocol
Parameter
Description
Fins Enable
If enabled, the code reader will output data via TCP/UDP FIN.
Fins Server IP
It sets the server IP of Fins.
Fins Server Port
It is 9600 by default.
Fins Control Poll Interval
(ms)
It sets how often read data.
Fins Control Space
It sets storage space of the control area.
Fins Control Offset
It sets the start offset address of the control area.
Fins Control Size (Word)
It sets the size of the control area.
Fins Status Space
It sets storage space of the status area.
Fins Status Offset
It sets the start offset address of the status area.
Fins Status Size (Word)
It sets the size of the status area.
Fins Result Space
It sets storage space of the result area.
Fins Result Offset
It sets the start offset address of the result area.
Fins Result Size (Word)
It sets the size of the result area.
Fins Result Byte Swap
If it is enabled, the client software will swap Fins results.
Fins Result Timeout (s)
It sets the Fins result timeout, and the unit is s.