ID2000 Series Industrial Code Reader User Manual
55
Parameter 1
Exposure Time 1
Gain 1
Gamma 1
Lighting 1
Parameter 2
Exposure Time 2
Gain 2
Gamma 2
Lighting 2
Parameter 3
Exposure Time 3
Gain 3
Gamma 3
Lighting 3
Parameter 4
Exposure Time 4
Gain 4
Gamma 4
Lighting 4
Parameter 8
Exposure Time 8
Gain 8
Gamma 8
Lighting 8
Parameter 7
Exposure Time 7
Gain 7
Gamma 7
Lighting 7
Parameter 6
Exposure Time 6
Gain 6
Gamma 6
Lighting 6
Parameter 5
Exposure Time 5
Gain 5
Gamma 5
Lighting 5
Figure 9-6 Polling Diagram
9.3.3 Set Light Source
Light source control allows you to enable the device’s aiming system and light source, and
set related parameters according to actual demands.
Note
Light source parameters may differ by device models.
Make sure you have selected the device to be set in Device Connection before setting
light source parameters.
Type I Device to Type VI Device
Steps
1. Go to Image Settings Light, and enable Aiming Light Enable according to actual
demands.
2. Enable Lighting Enable to enable the light source according to actual demands.
3. (Optional) Set Lighting Duration and Precharge Time if Lighting Enable is enabled.
Figure 9-7 Set Light Source (Type I Device to Type VI Device)