ID2000 Series Industrial Code Reader User Manual
105
2. Go to feature tree, find Diagnose Event Report.
3. View relation information.
4. (Optional) Click Execute in Reset Event to clear all information.
Figure 9-52 Event Report
9.15 User Set Customization
In Configuration Management, you can set and manage the user set. A user set is a group
of parameter values with all the settings needed to control the device, and you can save,
load and switch different user sets.
Save Settings: If you have set the device parameters as desired, you can save them into
the user set. Go to Config Management Save Settings, and click UserSet1, UserSet2,
or UserSet3 to save the current device settings.
Load Settings: You can load the user set to restore the device to the saved group of
parameter values again if required. Go to Config Management Load Settings, and
click Default, UserSet1, UserSet2, or UserSet3 to load settings.
Note
The Default refers to restore the device parameter settings to the factory ones.
Start Settings: The selected user set will be automatically loaded after the device being
powered on. For example, if you select Default, the device parameter settings will be
restored to the factory settings.