ID2000 Series Industrial Code Reader User Manual
99
Steps
1. Right click the device in Device Connection, and click Feature Tree.
2. Go to Multi Camera Control, set one device as Main in Multi Camera Mode according to
actual demands.
Note
You can set 32 sub devices at most.
Figure 9-47 Set Multicamera Mode
3. Set GroupID.
Note
You should set the same GroupID for devices in the same multicast system.
9.11 Main-Sub Networking
When multiple devices acquire images and parse codes at the same time, the main-sub
networking function enables multiple devices to work together.
The main principle of main-sub networking is to set one of the multiple devices as the main
device (main station), and the other devices as sub devices (sub station). The sub devices
send the code results to the main device that integrates or forwards, and sends the code
results to the connected PC or client software to realize the collaborative work function of
multiple devices.
Before You Start
Make sure that the device mode is Normal and Tigger Mode is On before using this function.
Note
The function of main-sub networking may differ by device models.
Steps
1. Go to Multi Camera Control, and select Multi Station Work Mode according to actual
demands.
●
Off: This function is disabled.
●
Independent: The main device and the sub devices are triggered respectively, and the sub
devices send the code reading result to the main device. The main device directly formats