ID2000 Series Industrial Code Reader User Manual
100
and outputs the sub devices’ data according to the formatting rules without data
processing. It is mainly used for the scenario of multiple assembly lines.
●
Cooperation: The main device and the sub devices use the same trigger, the sub devices
send the code reading result to the main device for data processing, and then format and
output the data after the fusion of the main and sub devices according to the formatting
rules. It is mainly used to the scenario where the field of view is insufficient, and multiple
codes are read together to integrate the output. In most cases, this mode is used.
2. Set role for different devices in Station Role. Main is the main device, and Sub is the sub
device
Note
There is one main device only in the same main-sub networking (same group ID).
3. Set Station Port to configure the main station’s port number and communicate with the
sub station.
4. (Optional) Enable Client Display Sub Enable to let the main device display the code
reading images from the sub station.
Note
The client software of the main device can acquire images after enabling Client Display Sub
Enable.
5. Set MS Group ID ranging from 100 to 200 to configure the main-sub networking group
ID.
Note
Two-way visiting is not allowing among different network groups.
6. (Optional) View enumerated sub station quantity via Sub Station Total as a main station
role.
7. (Optional) View sub station information after entering Query Sub Station ID as a main
station role.
●
Sub Station IP: The IP information of the sub station.
●
Sub Station Connect: The connection status of the sub station. 1 stands for normal data
transmission. Otherwise, it is disconnected.
●
Sub Station UN: The user name information of the sub station.
●
Sub Station MN: The product model information of the sub station.
●
Sub Station SN: The serial number of the sub station.
8. (Optional) View main station information when the Station Role is Sub.
●
Main Station IP: The IP information of the main station.
●
Main Station Connect: The connection status of the main station. 1 stands for normal
data transmission. Otherwise, it is disconnected.
●
Main Station UN: The user name information of the main station.
●
Main Station MN: The product model information of the main station.
●
Main Station SN: The serial number of the main station.