ID2000 Series Industrial Code Reader User Manual
72
codes and outputs overall grade.
Note
●
The specific parameters may differ by device models and firmware versions.
●
Make sure that the device’s operation mode is normal and 2D codes added.
Steps
1. Go to Algorithm Control → Algorithm Parameter, and select 2D Code as Arithmetic Type.
2. Enable 2D Code Quality Evaluation.
3. Set Iso Edition, including Iso15415 and Iso29158
●
Iso15415 is applicable to the quality evaluation for label 2-dimensional codes.
●
Iso29158 is applicable to the quality evaluation for DPM format 2-dimensional codes.
4. Refer to step 5 to step 7 in Set 1D Code Quality Evaluation to set other parameters.
9.4.5 Set Code Score
The code score function evaluates the code-reading environment for codes and outputs
code score.
Note
●
The function of code score may differ by device models.
●
In test mode, this function is enabled by default. In normal mode, you need to enable it
manually.
●
The code score is determined by two factors including image quality and print quality of
codes. The range of code score is between 0 and 100, and the higher the score, and easier
the code can be read.
Steps
1. Go to Algorithm Settings, and enable Code Score Enable.
Figure 9-26 Enable Code Score Enable