ID2000 Series Industrial Code Reader User Manual
103
If the third code is kl99fjkd, and comparison fails. The preset value does not increase.
If the fourth code is kl00djf, and comparison succeeds. The preset value increases to 02
(00+2).
Figure 9-50 Consecutive Number Contrast
9.13 Statistics Information
The statistics information in the feature tree helps you to count data related with code
reading.
Note
You need to set device’s operation mode as normal before using this function.
Steps
1. Right click the device in Device Connection, and click Feature Tree.
2. Go to feature tree, find Statistics Info., and select Statistics Mode:
All Frames means the client software will display all data since the device is powered on.
Latest Frames means the client software will display data of the last 10 frames.
3. View related parameters.
4. (Optional) Click Execute in Reset Statistics to reset statistics information.
Table 9-20 Parameter Description
Parameter Name
Description
Total Frame Number
The total frame quantity.
Read Frame Number
The quantity of frames that have been read codes.
Noread Frame Number
The quantity of frames that have not been read codes.
Read Rate
It refers to the code reading ratio.