ID2000 Series Industrial Code Reader User Manual
89
Table 9-13 MELSEC/SLMP Communication Protocol
If enabled, the code reader will output data via MELSEC
protocol.
IP address of the Programmable Logic Controller (PLC)
connected to the code reader.
Port number of the Programmable Logic Controller (PLC)
connected to the code reader.
Frame type of the MELSEC.
Network number to communicate with.
Node number to communicate with.
Processor number to communicate with.
MELSEC Control Poll
Interval
Requested time between successive polls of the control
block from the PLC.
It sets storage space of the control area.
It sets the start offset address of the control area.
MELSEC Control Size
(Word)
It sets the size of the control area.
It sets storage space of the status area.
It sets the start offset address of the status area.
MELSEC Status Size (Word)
It sets the size of the status area.
It sets storage space of the result area.
It sets the start offset address of the result area.
MELSEC Result Size (World)
It sets the size of the result area.
If it is enabled, the client software will swap MELSEC
results.
It sets the MELSEC result timeout, and the unit is s.
9.8.8 Set Ethernet/IP
If you select EthernetIp as the communication protocol, you can configure the following
parameters: