ID2000 Series Industrial Code Reader User Manual
83
9.7.3 Set Event Source
The device supports outputting different trigger signals according to the event source you
select. Click I/O Control Settings Output Line Out Activation Event to select event
source.
The device supports following event sources, including Off, NoCodeRead, ReadSuccess,
Compare Success, and Compare Fail.
Note
Off refers to no event source.
The event source parameters may differ by device model.
No Code Read: If no code read by the device, the output signal will be triggered.
Read Success: If the code is read by the device, the output signal will be triggered.
Compare Success: If data comparison is successful, the output signal will be triggered.
Compare Fail: If data comparison is failed, the output signal will be triggered.
Command Control IO: It is controlled by the communication strings.
Note
You need to set different parameters when selecting these event sources.
Select No Code Read
If you select No Code Read as Line Out Activation Event, and you can set its output delay
time and duration.
Line Out Delay Time: It sets the delay time for outputting the output signal.
Line Out Duration: It sets the time duration of the output signal.
Figure 9-38 Select No Code Read
Select Read Success
If you select Read Success as Line Out Activation Event, and you can set its output delay
time and duration.
Line Out Delay Time: It sets the delay time for outputting the output signal.
Line Out Duration: It sets the time duration of the output signal.