9.3.6 Set Self-Adaptive Adjustment
The function of self-adaptive adjustment can automatically adjust exposure, gain, Gamma
and other parameters to have a better code reading effect.
Note
The function of self-adaptive adjustment may differ by device models.
Steps
1. Go to Image Settings Smart Tune Control Self Adapt Adjust, and unfold Self
Adapt Adjust.
2. Select Adjust Source according to actual demands.
Figure 9-15 Select Adjust Source
Default Param: It adjusts the default parameters.
Polling Param: It adjusts parameters configured in polling. After Polling Param is selected
as Adjust Source, you should select a polling parameter group from Polling Param and
enable or disable Focus Enable.
Figure 9-16 Polling Parameter
3. Set Exposure Max or Gain Max according to actual demands.
Exposure Max: It sets the max. exposure during the self-adaptive adjustment.
Gain Max: It sets the max. gain during the self-adaptive adjustment.
4. (Optional) Set self-adaptive code type in Code Type Mode.
Code Self-Adaptive: All code types added in field of view will be self-adaptive.