EasyManua.ls Logo

HikRobot ID2000 Series - Output Signal Wiring

HikRobot ID2000 Series
140 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
ID2000 Series Industrial Code Reader User Manual
28
Opto-isolated
Input
DB9 Connector
NPN Device
NPN Device Power
NPN Power Ground
Signal Line
VCC
GND of PWR
Input Signal Ground
GND of VCC
Internal Resistor
of Cable
Figure 6-6 Input Signal Connecting to NPN Device (Pull-Up Resistor of 17-Pin Cable Used)
If the VCC of NPN device is 12 VDC or 24 VDC and the external pull-up resistor is used, it is
recommended to use 1 KΩ pull-up resistor.
Opto-isolated
Input
DB9 Connector
NPN
Device
NPN Device Power
NPN Power Ground
Signal Line
VCC
GND of PWR
Input Signal Ground
GND of VCC
Figure 6-7 Input Signal Connecting to NPN Device (External Pull-Up Resistor Used)
6.1.4 Output Signal Wiring
Note
Output signal wiring may differ by external device types.
The supplied 17-pin cable of type V device has pull-up and pull-down resistors.
The voltage of VCC should be equal to or less than that of PWR. Otherwise, the output
signal exception may occur.
PNP Device
Opto-isolated
Output
DB9 Connector
PNP
Device
PNP Device Power
PNP Power Ground
Signal Line
VCC
GND of PWR
Output Signal Ground
GND of VCC
Figure 6-8 Output Signal Connecting to PNP Device

Table of Contents