ID2000 Series Industrial Code Reader User Manual
50
Steps
1. Right click the device in Device Connection, and click Feature Tree.
2. Go to Trigger and IO Control → Accurate Mode Enable, and enable Accurate Mode
Enable.
Note
Enabling Accurate Mode Enable is accurate mode, and disable it is batch mode.
Figure 9-2 Code Reading Mode Settings
Table 9-2 Parameters Description
It reads codes containing the cross laser center in the code
area only. The code reading process ends if codes are read
successfully or the trigger switch is released.
It can read multiple codes when the trigger switch is pressed.
After code reading is finished, the result will be packaged and
outputted. The code reading process ends if expected code
quantity is reached or exceeded, code reading timed out,
valid frame quantity is reached, or the trigger switch is
released.
Note
The function of code reading mode may differ by device models.
9.3 Image Quality Settings
This section introduces how to set image related parameters of the device via client
software.
Note
For different models of the device, the specific parameters may differ, and the actual device
you purchased shall prevail.