ID2000 Series Industrial Code Reader User Manual
29
NPN Device
If the VCC of NPN device is 12 VDC or 24 VDC, and the pull-up resistor of the supplied 17-
pin cable is used.
Figure 6-9 Output Signal Connecting to NPN Device (Pull-Up Resistor of 17-Pin Cable Used)
If the VCC of NPN device is 12 VDC or 24 VDC and the external pull-up resistor is used, it is
recommended to use 1 KΩ pull-up resistor.
Figure 6-10 Output Signal Connecting to NPN Device (External Pull-Up Resistor Used)
6.2 I/O Electrical Feature and Wiring of Other Devices
The other devices include type I to type IV devices, and type VI and type VII devices. With
different device types, their I/O electrical feature varies.
●
Type II device: Its Line 0/1/2/3 are all bi-directional signals.
●
Type I, type III, type IV and type VI devices: Their Line 2 is non-isolated input signal, Line
3 is non-isolated output signal, and Line 0/1 are both bi-directional signals.
●
Type VII device: Its LineIn 1 is non-isolated input signal, LineOut 3 is non-isolated output
signal, and Line 2 is bi-directional signal.