EasyManua.ls Logo

HikRobot ID2000 Series - Opto-Isolated Output Circuit

HikRobot ID2000 Series
140 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
ID2000 Series Industrial Code Reader User Manual
26
Table 6-1 Input Electrical Feature
Parameter Name
Symbol
Value
Input Logic Level Low
VL
1.5 VDC
Input Logic Level High
VH
2 VDC
Input Falling Delay
TDF
81.6 μs
Input Rising Delay
TDR
7 μs
6.1.2 Opto-isolated Output Circuit
Type V device's LineOut 0/1 are opto-isolated outputs, and internal circuit is as follows.
Note
The output voltage ranges from 5 VDC to 30 VDC.
The maximum output current is 25 mA.
Do not directly connect with inductive load (e.g. DC motor, etc.) when outputting.
If the external voltage and resistance change, the corresponding current of output signal
and output logic level low may differ.
Figure 6-3 Internal Circuit of Output Signal
Figure 6-4 Output Logic Level