ID2000 Series Industrial Code Reader User Manual
46
Figure 8-2 Select Operation Mode
Note
Stopping the real-time acquisition is required before selecting the operation mode.
Table 8-3 Operation Mode Description
It is used during device debugging. The device outputs images that
are acquired in real-time, and displays code information.
It is used during device normal operation. After reading code in
image, the device outputs image and code information.
It is used during testing image data. The device outputs raw data and
displays code information.
2. Click in the live view window to view images and the code reading effect.
Figure 8-3 Code Reading Effect
Note
If the effect is not very good, you can adjust the focus knob (type II and type III devices only)
or via auto focus function (type I device only) or related parameters like exposure time, gain,
etc. in the Image Settings area.