5.3 Measurement specifications
139
Measurement accuracy For more information about the measurement accuracy for input from external current
sensors, see "Measurement accuracy" (p.152).
Values for f.s. depend on measurement ranges.
“F” in the tables refers to the frequency in kHz.
When using the 1 mA/ 2 mA range
Add ±1 A to 0.1 Hz to 100 kHz measurement accuracy for current.
Add (±1 A) × (voltage read value) to 0.1 Hz to 100 kHz measurement accuracy for
active power.
When using the 200 mA/ 500 mA/ 1 A/ 2 A/ 5 A/ 10 A/ 20 A range
Add ±1 mA to DC measurement accuracy for current.
Add (±1 mA) × (voltage read value) to DC measurement accuracy for active power.
When using the 1 mA/ 2 mA/ 5 mA/ 10 mA/ 20 mA/ 50 mA/ 100 mA range
Add ±10 A to DC measurement accuracy for current.
Add (±10 A) × (voltage read value) to DC measurement accuracy for active power.
When using the 200 mA/ 500 mA/ 1 A/ 2 A/ 5 A/ 10 A/ 20 A range
Add ±(0.02×F)% rdg. to the measurement accuracy for current and active power for
which (10 kHz < f 100 kHz).
The following input are considered reference values:
Values for voltage, current, and active power for which 0.1 Hz f < 10 Hz.
Values for voltage, current, and active power in excess of 220 V or 20 A for which
10 Hz f < 16 Hz.
Values for current and active power in excess of 20 A for which 500 Hz < f 50 kHz.
Values for current and active power in excess of 10 A for which 50 kHz < f 100 kHz.
Values for voltage and active power in excess of 750 V for which 30 kHz < f 100 kHz.
Voltage
Frequency (f) Input < 50%f.s. 50%f.s. Input < 100%f.s. 100%f.s. Input
DC
±0.1% rdg.±0.1%f.s. ±0.1% rdg.±0.1%f.s. ±0.2% rdg.
0.1 Hz f < 16 Hz ±0.1% rdg.±0.2%f.s. ±0.3% rdg. ±0.3% rdg.
16 Hz f < 45 Hz ±0.1% rdg.±0.1%f.s. ±0.2% rdg. ±0.2% rdg.
45 Hz f 66 Hz ±0.1% rdg.±0.05%f.s. ±0.15% rdg. ±0.15% rdg.
66 Hz < f 500 Hz ±0.1% rdg.±0.1%f.s. ±0.2% rdg. ±0.2% rdg.
500 Hz < f 10 kHz ±0.1% rdg.±0.2%f.s. ±0.3% rdg. ±0.3% rdg.
10 kHz < f 50 kHz ±0.5% rdg.±0.3%f.s. ±0.8% rdg. ±0.8% rdg.
50 kHz < f 100 kHz ±2.1% rdg.±0.3%f.s. ±2.4% rdg. ±2.4% rdg.
Current
Frequency (f) Input < 50%f.s. 50%f.s. Input < 100%f.s. 100%f.s. Input
DC ±0.1% rdg.±0.1%f.s. ±0.1% rdg.±0.1%f.s. ±0.2% rdg.
0.1 Hz f < 16 Hz ±0.1% rdg.±0.2%f.s. ±0.3% rdg. ±0.3% rdg.
16 Hz f < 45 Hz ±0.1% rdg.±0.1%f.s. ±0.2% rdg. ±0.2% rdg.
45 Hz f 66 Hz ±0.1% rdg.±0.05%f.s. ±0.15% rdg. ±0.15% rdg.
66 Hz < f 500 Hz ±0.1% rdg.±0.1%f.s. ±0.2% rdg. ±0.2% rdg.
500 Hz < f 1 kHz ±0.1% rdg.±0.2%f.s. ±0.3% rdg. ±0.3% rdg.
1 kHz < f 10 kHz ±(0.03+0.07×F)% rdg.±0.2%f.s. ±(0.23+0.07×F)% rdg. ±(0.23+0.07×F)% rdg.
10 kHz < f 100 kHz ±(0.3+0.04×F)% rdg.±0.3%f.s. ±(0.6+0.04×F)% rdg. ±(0.6+0.04×F)% rdg.
Active power
Frequency (f) Input < 50%f.s. 50%f.s. Input < 100%f.s. 100%f.s. Input
DC ±0.1% rdg.±0.1%f.s. ±0.1% rdg.±0.1%f.s. ±0.2% rdg.
0.1 Hz f < 16 Hz ±0.1% rdg.±0.2%f.s. ±0.3% rdg. ±0.3% rdg.
16 Hz f < 45 Hz ±0.1% rdg.±0.1%f.s. ±0.2% rdg. ±0.2% rdg.
45 Hz f 66 Hz ±0.1% rdg.±0.05%f.s. ±0.15% rdg. ±0.15% rdg.
66 Hz < f 500 Hz ±0.1% rdg.±0.1%f.s. ±0.2% rdg. ±0.2% rdg.
500 Hz < f 1 kHz ±0.1% rdg.±0.2%f.s. ±0.3% rdg. ±0.3% rdg.
1 kHz < f 10 kHz ±(0.03+0.07×F)% rdg.±0.2%f.s. ±(0.23+0.07×F)% rdg. ±(0.23+0.07×F)% rdg.
10 kHz < f 50 kHz ±(0.07×F)% rdg.±0.3%f.s. ±(0.3+0.07×F)% rdg. ±(0.3+0.07×F)% rdg.
50 kHz < f 100 kHz ±(0.6+0.07×F)% rdg.±0.3%f.s. ±(0.9+0.07×F)% rdg. ±(0.9+0.07×F)% rdg.