5.3 Measurement specifications
151
When using a current sensor with a rating of 200 A (with the CT ratio set to 40)
9272-10 (200 A): TYPE.2; 9278: TYPE.2; CT6863: TYPE.2; CT6843: TYPE.2
When using a current sensor with a rating of 500 A (with the CT ratio set to 100)
9661: TYPE.1; CT9667 (500 A): TYPE.1; 9279: TYPE.2; 9709: TYPE.2
When using a current sensor with a rating of 1,000 A (with the CT ratio set to 200)
9669: TYPE.1: CT6865: TYPE.2
When using a current sensor with a rating of 5,000 A (with the CT ratio set to 1000)
CT9667 (5,000 A): TYPE.1
When using the 9660 (TYPE.1) (rated current: 100 A; with the CT ratio set to 100)
Range noted
on panel
Current
range
Voltage range
6.0000 V 15.000 V 30.000 V 60.000 V 150.00 V 300.00 V 600.00 V 1.0000 kV
1 A 40.000 A 240.00 600.00 1.2000 k 2.4000 k 6.0000 k 12.000 k 24.000 k 40.000 k
2 A 80.000 A 480.00 1.2000 k 2.4000 k 4.8000 k 12.000 k 24.000 k 48.000 k 80.000 k
5 A 200.00 A 1.2000 k 3.0000 k 6.0000 k 12.000 k 30.000 k 60.000 k 120.00 k 200.00 k
Units: W (active power), VA (apparent power), var (reactive power)
Range noted
on panel
Current
range
Voltage range
6.0000 V 15.000 V 30.000 V 60.000 V 150.00 V 300.00 V 600.00 V 1.0000 kV
1 A 100.00 A 600.00 1.5000 k 3.0000 k 6.0000 k 15.000 k 30.000 k 60.000 k 100.00 k
2 A 200.00 A 1.2000 k 3.0000 k 6.0000 k 12.000 k 30.000 k 60.000 k 120.00 k 200.00 k
5 A 500.00 A 3.0000 k 7.5000 k 15.000 k 30.000 k 75.000 k 150.00 k 300.00 k 500.00 k
Units: W (active power), VA (apparent power), var (reactive power)
Range noted
on panel
Current
range
Voltage range
6.0000 V 15.000 V 30.000 V 60.000 V 150.00 V 300.00 V 600.00 V 1.0000 kV
1 A 200.00 A 1.2000 k 3.0000 k 6.0000 k 12.000 k 30.000 k 60.000 k 120.00 k 200.00 k
2 A 400.00 A 2.4000 k 6.0000 k 12.000 k 24.000 k 60.000 k 120.00 k 240.00 k 400.00 k
5 A 1.0000 kA 6.0000 k 15.000 k 30.000 k 60.000 k 150.00 k 300.00 k 600.00 k 1.0000 M
Units: W (active power), VA (apparent power), var (reactive power)
Range noted
on panel
Current
range
Voltage range
6.0000 V 15.000 V 30.000 V 60.000 V 150.00 V 300.00 V 600.00 V 1.0000 kV
1 A 1.0000 kA 6.0000 k 15.000 k 30.000 k 60.000 k 150.00 k 300.00 k 600.00 k 1.0000 M
2 A 2.0000 kA 12.000 k 30.000 k 60.000 k 120.00 k 300.00 k 600.00 k 1.2000 M 2.0000 M
5 A 5.0000 kA 30.000 k 75.000 k 150.00 k 300.00 k 750.00 k 1.5000 M 3.0000 M 5.0000 M
Units: W (active power), VA (apparent power), var (reactive power)
Range noted
on panel
Current
range
Voltage range
6.0000 V 15.000 V 30.000 V 60.000 V 150.00 V 300.00 V 600.00 V 1.0000 kV
1 A 100.00A 600.00 1.5000 k 3.0000 k 6.0000 k 15.000 k 30.000 k 60.000 k 100.00 k