EasyManuals Logo

Hitachi ZAXIS 120-6 class User Manual

Hitachi ZAXIS 120-6 class
536 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #242 background imageLoading...
Page #242 background image
3-4
OPERATING THE ENGINE
Starting the Engine
Starting the Engine in Ordinary Temperature
1. Confirm that pilot control shut-off lever (1) is in the LOCK
position.
2. Turn engine control dial (3) to the slow idle position.
3. Sound horn to alert bystanders
4. Insert key (2) to the key switch. Turn it to ON position.
5. "Wait-screen (nothing is displayed)" is displayed on the
monitor for 2 seconds. Regardless of pilot control shut-
off lever (1) position, the engine can not be cranked
during this moment.
6. When the Password Input screen is displayed on the
monitor, input the password. Unless the numeric keypad
function (ignition block system) is activated, this screen
is not displayed.
IMPORTANT: When required to activate the numeric
keypad function (ignition block system), consult your
authorized dealer.
MDAA-01-085EN
Password Input Screen
2
3
Slow Idle
1
LOCK Position
MDAA-01-295
MDC1-01-502
M1P1-01-068

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Hitachi ZAXIS 120-6 class and is the answer not in the manual?

Hitachi ZAXIS 120-6 class Specifications

General IconGeneral
BrandHitachi
ModelZAXIS 120-6 class
CategoryExcavators
LanguageEnglish

Related product manuals