Page #387 background image
7-93
MAINTENANCE
Check Coolant Level
--- daily
1. Confirm that pilot control shut-off lever (1) is in the LOCK
position.
2. Confirm that all control levers are placed in neutral.
3. Insert key switch (2). Turn it to ON position. Press and
hold switch (3) with the engine stopped.
Coolant indicator (4) must be displayed in green.
IMPORTANT: Do not rely only on the monitor display
for checking the machine conditions such as oil level;
visually check them yourself as required.
Always check the machine on a firm, level surface.
f
NOTE: If the security function is enabled, a password is
required.
2
1
LOCK position
MDAA-01-295
4
MDC1-01-502
MDC1-01-041
3
MDCD-01-026