11-3
TROUBLESHOOTING
Control Lever
Problem Cause Solution
Lever is heavy to operate. Rusted joint * Lubricate or repair
Worn pusher * Replace
Does not move smoothly. Worn pusher * Repair or replace
Faulty pilot valve * Replace
Does Not Return to Neutral. Faulty pilot valve * Replace
The lever is tilted in the neutral position
due to increase in play.
Worn joint * Repair or replace
Faulty pilot valve * Replace
Items with * mark: Consult your authorized dealer.