122 Voyager 1602g User Guide
Codabar Concatenation
Codabar supports symbol concatenation. When you enable concatenation, the
scanner looks for a Codabar symbol having a “D” start character, adjacent to a
symbol having a “D” stop character. In this case the two messages are concate-
nated into one with the “D” characters omitted.
Select Require to prevent the scanner from decoding a single “D” Codabar symbol
without its companion. This selection has no effect on Codabar symbols without
Stop/Start D characters. Default = Off.
Codabar Message Length
Scan the barcodes below to change the message length. Refer to Message Length
Description (page 120) for additional information. Minimum and Maximum
lengths = 2-60. Minimum Default = 4, Maximum Default = 60.
A1234D
D5678A
On
* Off
Require
Minimum Message Length
Maximum Message Length