48 Voyager 1602g User Guide
If your scanner is out range of the AP, an alarm sounds from the scanner. The alarm
stops when the scanner is moved closer to the AP, when the AP links to another
scanner, or when the alarm duration expires. To set the alarm duration, scan the
barcode below and then set the time-out duration (from 0-3000 seconds) by scan-
ning digits on the Programming Chart inside the back cover, then scanning Save.
Default = 0 sec (no alarm).
Note: If you are out of range when you scan a barcode, you will receive an error tone even if
you do not have the alarm set because the data could not be communicated to the AP.
Alarm Sound Type
Change the alarm type by scanning the following barcode and then scanning a
digit (0-7) barcode and the Save barcode on the Programming Chart inside the
back cover of this manual. Default = 0.
The sounds are as follows:
Scanner Alarm Duration
Setting Sound
0 3 long beeps, medium pitch
1 3 long beeps, high pitch
2 4 short beeps, medium pitch
3 4 short beeps, high pitch
4 single chirps, medium pitch
5 2 chirps, then 1 chirp, medium pitch
6 single chirps, high pitch
7 2 chirps, then 1 chirp, high pitch
Scanner Alarm Type