Voyager 1602g User Guide 75
range than Normal mode. Enhanced mode is best used when you require a very
fast scan speed and don’t require a long working range. Default = Manual Trigger-
Normal.
Serial Trigger Mode
You can activate the scanner either by pressing the scan button, or using a serial
trigger command (see Trigger Commands on page 180). You must be in a serial
interface mode in order to use serial triggering. Refer to RS232 Serial Port (page
21) or USB Serial (page 25) for further information. When in serial mode, the scan-
ner scans until a barcode has been read or until the deactivate command is sent.
The scanner can also be set to turn itself off after a specified time has elapsed (see
Read Time-Out, which follows).
Read Time-Out
Use this selection to set a time-out (in milliseconds) of the scan button when using
serial commands to trigger the scanner. Once the scanner has timed out, you can
activate the scanner either by pressing the scan button or using a serial trigger
command. After scanning the Read Time-Out barcode, set the time-out duration
(from 0-300,000 milliseconds) by scanning digits on the Programming Chart
inside the back cover, then scanning Save. Default = 30,000 ms.