40 Voyager 1602g User Guide
the host. Pressing the scan button, scanning an Access Point linking barcode, or
pairing the scanner with a host resets the attempt count and the scanner will again
try to link.
Scan the Maximum Link Attempts barcode, then scan the number of attempts for
the setting (from 0-100) from the Programming Chart. Scan Save to save the set-
ting. Default = 0.
Note: When Auto Reconnect Mode is On, setting Maximum Link Attempts to zero will cause
the scanner to try to link until the Scanner Power Time-Out Timer setting expires.
When Auto Reconnect Mode is Off, setting Maximum Link Attempts to zero will cause
the scanner to only attempt linking one time after a scan button press.
Relink Time-Out
Relink Time-Out controls the idle time between relink attempts. An attempt to link
a scanner to a host typically lasts up to 5 seconds. This is the time when the scan-
ner is actually attempting a contact. Relink Time-Out controls the amount of time,
in seconds, that elapses between the end of one connection attempt and the start
of the next.
Note: The length of time for an attempt depends on the number of scanners connected to
a host. An extra 7 seconds may be required when a connection is successful.
Scan the Relink Time-Out barcode, then scan the number of seconds for the set-
ting (from 1-100) from the Programming Chart. Scan Save to save the setting.
Default = 3 seconds.
Bluetooth/ISM Network Activity Examples
Default values
When the scanner goes out of range, the scanner repeatedly attempts to connect
to the host. Each attempt consists of approximately 5 seconds of active time fol-
lowed by 3 seconds of idle time. After one hour, the scanner powers off and batch
mode data is lost.
Maximum Link Attempts set to 15
Other values at default setting
Maximum Link Attempts
Relink Time-Out