HP ProLiant DL560 Gen11 - Results; Installing the E3.S drive cage; Prerequisites; About this task

HP ProLiant DL560 Gen11
238 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Install the processor mezzanine tray .
16. Install the access panel .
17. Installing the server into the rack .
18. Connect all peripheral cables to the server.
19. Connect each power cord to the power source.
20. Connect each power cord to the server.
21. Power up the server .
22. If removed, install the front bezel .
ResultsResults
The installation is complete.
Installing the Installing the E3.SE3.S drive cage drive cage
PrerequisitesPrerequisites
Before you perform this procedure, make sure that you have the following items available:
T-10 Torx screwdriver
T-15 Torx screwdriver
About this taskAbout this task
This E3.S drive cage option can be installed in Boxes 2–3.
CAUTION:CAUTION:
A discharge of static electricity from a finger or other conductor might damage system boards or other static-sensitive
devices. To prevent damage, observe antistatic precautions.
CAUTION:CAUTION: To prevent improper cooling and thermal damage, do not operate the server unless all bays are populated with
either a component or a blank.
ProcedureProcedure
1. If installed, remove the front bezel .
2. Power down the server.
3. If installed, open the cable management arm .
4. Remove all power:
a. Disconnect each power cord from the power source.
b. Disconnect each power cord from the server.
5. Disconnect all peripheral cables from the server.
6. Remove the server from the rack .
7. Place the server on a flat, level work surface.
8. Remove the access panel .
9. Do one of the following:
HPE ProLiant DL560 Gen11 Server User Guide 114