About this taskAbout this task
CAUTION:CAUTION:
A discharge of static electricity from a finger or other conductor might damage system boards or other static-sensitive
devices. To prevent damage, observe antistatic precautions.
ProcedureProcedure
1. Power down the server.
2. If installed, open the cable management arm .
3. Remove all power:
a. Disconnect each power cord from the power source.
b. Disconnect each power cord from the server.
4. Disconnect all peripheral cables from the server.
5. Remove the server from the rack .
6. Place the server on a flat, level work surface.
7. Remove the access panel .
8. Remove the riser cage.
9. (Optional) Install the riser board.
10. Remove the riser slot blank.
11. Install the type-p storage controller.
a. Install the type-p storage controller (callout 1), and install the screw (callout 2).
Make sure that the controller is seated firmly in the slot.
b. Close the riser cage latch (callout 3).