Remove the air baffleRemove the air baffle
About this taskAbout this task
The air baffle must be installed in the dual-processor configuration.
CAUTION:CAUTION: For proper cooling, do not operate the server without the access panel, baffles, expansion slot covers, or blanks
installed. If the server supports hot-plug components, minimize the amount of time the access panel is open.
ProcedureProcedure
1. Power down the server.
2. If installed, open the cable management arm .
3. Remove all power:
a. Disconnect each power cord from the power source.
b. Disconnect each power cord from the server.
4. Disconnect all peripheral cables from the server.
5. Do one of the following:
Extend the server from the rack .
Remove the server from the rack .
6. Remove the access panel .
7. Remove the air baffle.