Table 7 CLI configuration commands
Command
Usage
1
updateFC
ChangesthedefaultFChostportconnectionsettings. Where
the options are:
-a <n> - ID number of node to modify (0, ...) (optional)
-i <n> - Fibre Channel index (0, 1, ...) (required)
-l <n> - If attached in arbitrated loop mode, specifies a
hard ALPA value between 0 and 125. A value of -1 specifies
a dynamically assigned ALPA. If not attached to an arbitrated
loop, this parameter is ignored (required)
-r <n> - Port number of the FC por t to modify (required)
-s <n> - P referred speed(s) (0-Auto, 1-One GB, 2-Two GB,
4-Four GB, or 10-Ten GB) (required)
-t <n> - Preferred topology(s) (0-Auto, 1-Point to Point, 2-Loop ,
3-Fabric, or 4-Public Loop) (required)
-h - Displays command usage information (optional)
setOverSubscription
Enables or disables oversubscription and specifies the percent
storage remaining for notification. Where the options are:
-e <n> - Enable/disable oversubscription (0-Disabled or
1-Enabled) (required)
-p <n> - Percentage of capacity remaining for alert notifi cation
(required)
-h - Displays command usage information (optional)
getOverSubscription
Returns whether the oversubscription feature is enabled or
disabled and the capacity remaining percentage for notifica tion
alert. Oversubscription is enabled when "enabled = 0".
Oversubscription is disabled when "enabled = 1".
getLunMap
Returns existing LUN mapping configured on the VLS for the
LUN specified. Where the options are:
-a <n> - N umber of the node (0, ...) (required)
-l <n> - LUN number of devi ce whose LUN map y ou wish
to view (required)
-h - Displays command usage information (optional)
getLibTypes
Returns a list of available library emulation types. Displays
each library emulation’s name, type, product, revision, and
vendor information.
createLibrary
Creates a new library with the specified maximum number of
cartridge slots, input/export ports, and tape drives. Where
the options are:
-a <n> - Node ID of the node on which the library emulation
will reside (0, ...) (required)
-l <n> - LUN number to assign to library (-1 to 128) (optional)
-n <n> - Maximum number of tape drives (required)
-p <s> - Product (spa ces allowed) (MSL6000, ...) (required)
-pm <n> - FC por t to which this library is mapped (0, 1, ...)
(required)
-pt <n> - Maximum number of input/export ports (required)
-r <s> - Revision (0430, ...) (required)
-sl <n> - Maximum number of cartridge slots (required)
-t <s> - Library type name (required)
-v <s> -Vendor(HP,...) (required)
-y <n> - Library type to emulate (2051, ...) (required)
-h - Displays command usage information (optional)