138 Fibre Alliance MIB Objects
Table 30 lists the trap information returned for the connUnitEventDescr variable.
connUnitSensorStatusChange (1.3.6.1.3.94.0.5)
The overall status of the connectivity unit has changed. The recommended severity level (for filtering) is
alert. Sent whenever any of the following notifications occur:
Chassis.PsBadAlarm
Chassis.PsOkAlarm
Chassis.FanBadAlarm
Chassis.FanOkAlarm
Blade.OverheatAlarm
Blade.OverwarmAlarm
Variables:
{ connUnitSensorStatus }
Table 30 Filter trap levels
Trap type Cause Filter level
connUnitPortStatusChange User port config change
User port state change
E_Port alarm
eventSeverity_info
eventSeverity_info
eventSeverity_critical
connUnitDeletedTrap Fabric change and unit deleted eventSeverity_info
connUnitStatusChange Switch state change
Switch reset
eventSeverity_info
eventSeverity_critical
connUnitSensorStatusChange Power supply bad alarm
Power supply OK alarm
Fan bad alarm
Fan OK alarm
Overheat alarm
Overwarm alarm
Temperature OK alarm
eventSeverity_critical
eventSeverity_critical
eventSeverity_critical
eventSeverity_critical
eventSeverity_critical
eventSeverity_critical
eventSeverity_critical
connUnitEventTrap SNMP config change
Switch config change
System config change
Topology change
Zoning change
Zoning merge failure
NameServer change
Generic alarm
Generic event
eventSeverity_info
eventSeverity_info
eventSeverity_info
eventSeverity_info
eventSeverity_info
eventSeverity_critical
eventSeverity_info
eventSeverity_critical
eventSeverity_warning